8ee893e added `up < lastUp` beside the started_at comparison, to catch a restart landing in
the same whole second as the one the page last read. It cannot catch that. uptime_s is
derived, not independent: unix_now() - started_at_, both whole seconds, so started_at +
uptime_s is exactly the wall clock at every poll. Two processes sharing a started_at are
therefore read at increasing wall times and report INCREASING uptimes, so the comparison
never fires in the case it was written for. It fires on genuine restarts, which started_at
already catches, and on a backward NTP step, which is not a restart at all. Net effect: dead
where it was needed, redundant elsewhere, and a false clear of the session extremes on every
clock correction.
The test that "proved" it worked was fed an impossible fixture: started_at 100 with uptime 40
implies the clock read 140, then started_at 100 with uptime 2 implies 102. Time running
backwards is the only way to reach that pair, which is the same mistake the finding it
answered was about -- reasoning from a state the instrument cannot produce. It now asserts
the reachable behaviour instead: a backward uptime with an unchanged started_at is a clock
step and must NOT clear the extremes, since they still belong to the running process.
The collision the comparison tried to close needs a replacement process stamped in the same
second as the one the page last read. The page can only learn started_at once /stats answers,
startup_s after the old process began -- 69 s on this engine -- so a replacement starting
after its predecessor stopped answering is stamped a later second. The bound is startup_s >=
1 s; a model that came up inside a second could collide, and would cost one stale extreme
carrying a true age. That is documented where the comparison used to be.
The acceptance window's use of the same signal is NOT redundant and is untouched: it has no
started_at comparison, so for a tab that stopped polling while a new process drafted past the
old totals, a falling uptime is the only thing that catches the restart.
Verified: dashboard_test 241 checks over 8 cases, extremes.test.js 27, poll_spark.test.js 35,
sched_test 62646 over 184, no failures. Mutation re-run after the revert: deleting poll()'s
detection line, stamping extAtS on every sample, and deadening acceptTriple's age clause each
fail the suite. Behavior is unchanged from the deployed build, which never had the
comparison, so no restart is needed for this.
Authored at: Memoria Qwen 3.8 Flash-Next 125B MoE (level not visible) via Open WebUI