This repository has been archived on 2026-11-24. You can view files and clone it. You cannot open issues or pull requests or push a commit.
Files
radiance-sycl/libref
gearwave00001andClaude 8785774fc0 sampler: res_multistep (DPM++2M data-pred) as a per-request field; ABI 24
Radiance's video denoising had only first-order Euler. The DaSiWa reference
workflow samples MiniMax-H3 with res_multistep + simple, so add it as a second
order option, exposed as a `sampler` field on /v1/videos (default euler).

New op `flow_res_multistep` across all three kernel tiers (device==avx==libref),
closed form reusing the driver's per-step scalars:
  x' = r*x + hb1*den + hb2*x0,  den = x + sigma*v,  r = sigma_next/sigma
  order 2: h=ln(sg/sgn), h_last=ln(sg_prev/sg), r_s=h_last/h,
           hb1=(1-r)(1+1/(2 r_s)), hb2=-(1-r)/(2 r_s)
hb1+hb2 == 1-r, so it collapses to Euler when x0==den. Order 1 (Euler) is forced
at the first step, the first full-size step after a latent upscale (stale
history), and the last step (sigma_next==0); order 2 otherwise. The previous
denoised estimate persists in new PERSIST buffers b_vx0/b_ax0. Verified equal to
k-diffusion sample_dpmpp_2m to 5.6e-17 on three sigma grids.

- ABI 23->24: trailing int32_t sampler on RadVideoGenBatch; RAD_SAMPLER_EULER=0
  / RAD_SAMPLER_RES_MULTISTEP=1 in rad_runtime.h.
- driver: R_SCHED region widened 6->16 f32 ([0..5] Euler, [6..10] video coeffs,
  [11..15] audio); step_dit branches on V->sampler.
- server: `sampler` string field ("euler"/empty, "res_multistep", else
  invalid_request_error with the supported list); echoed on the job object;
  capabilities advertise video_samplers.

Tests: rad-avx-check 816 + 451 hand-built, 0 fail (left-assoc grouping matches
ref/device at tol 0); r4d_selftest --case flow_res_multistep_f32 f32|bf16 x
order {1,2} exact, both INOUT pitch gaps untouched.

Device-verified (TP2, fp8 container, 256^2/2s/10-step, seed 1234 identical):
both samplers complete clean 73-frame h264; outputs differ (branch genuinely
consumed, not ignored); bad value rejected; field omitted -> euler. res_multistep
renders warmer/higher-contrast than euler -- a tone lever, not an over-exposure
fix. The euler default path is unchanged.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-10-20 18:28:49 -05:00
..
2026-10-16 18:25:18 +02:00
2026-10-18 11:38:37 +02:00
2026-10-16 18:25:18 +02:00
2026-10-18 11:38:37 +02:00
2026-10-16 18:25:18 +02:00
2026-10-16 18:25:18 +02:00
2026-10-16 18:25:18 +02:00
2026-10-16 18:25:18 +02:00
2026-10-18 11:38:37 +02:00
2026-10-16 18:25:18 +02:00
2026-10-16 18:25:18 +02:00
2026-10-16 18:25:18 +02:00
2026-10-16 18:25:18 +02:00
2026-10-16 18:25:18 +02:00
2026-10-18 11:38:37 +02:00
2026-10-16 18:25:18 +02:00
2026-10-18 11:38:37 +02:00