Archived
Removed the 215W cap + −75mV undervolt, re-ran bench2.sh. Uncapped vs capped: ~2% at 6s, 5.3% at 12s (207→196), noise elsewhere; busy=100% on 519/528 samples. Conclusion: TP2 diffusion is NOT SM-clock-bound — the gain is small because the step waits on the gen4 x8 fabric (all-reduce + embedding/encoder reads over the link), which doesn't shrink with core clock. Corrects the earlier note that implied the cap was a major long-row handicap; the sol 12s gap is not the power cap — the link cap is. Leaving the box at 215W costs ~5% worst-case on diffusion. Co-Authored-By: Claude <noreply@anthropic.com>